70-00143-01-01 Proprietary Redline Communications © 2011 Page 43 of 52 March 9, 2011
4.2 Recovering From a Lost IP Address
If the password is known, the RDL-2000 can easily be recovered from the lockout
causes listed below.
Table 7: Maintenance - Recovery from System Lockout
Connect Link Manager on local subnet and start
session (S).
Management VLAN ID is unknown or
VLAN network services are not
available.
Connect Link Manager on local subnet and start
session (S).
Subnet mask set incorrectly.
Connect Link Manager on local subnet and start
session (S).
Contact Redline for service.
Recovery Procedure:
1. Use an Ethernet cable to connect the PC (with Link Manager installed) directly to the
PoE or to the network segment (subnet) connected to the PoE.
2. Click the S button (or press CTRL-S) to start a session. The Link Manager will
automatically discover the RDL-2000 unit.Choose the required RDL-2000 from the
list to start a session.
3. Modify the IP address and submit the new settings to restore normal access to the
RDL-2000 unit.