70-00143-01-01 Proprietary Redline Communications © 2011 Page 40 of 52 March 9, 2011
3.13 Debug
Use this screen to observe operating statistics for the wireless link.
Note: This feature is provided as a general diagnostic and troubleshooting tool only and
is not
a valid test for benchmarking performance of the wireless interface.
Important: This feature may halt all data traffic on the wireless link. This test should be
performed only during installation or a scheduled maintenance window.
Figure 26: Link Mgr - Debug Screen
Debug Counters
Common controls for the transmitter and receiver statistics.
Start / Stop: Click this button to start and stop collecting statistics.
Clear: Click this button to reset all counters.
Graph: Click this button to display a graph of the Tx and Rx throughput.
Figure 27: Link Mgr - Debug Screen Throughput Graph
Tx
Statistics for the transmitter section of the air interface.
Max Queue Length (Bytes): Maximum amount of data that can be queued for
transmission.
Queue Length (Bytes): Maximum amount of Tx data that has been saved in the Tx queue.
Tx packets are dropped if this length exceeds the Max Queue Length.
Requests (Packets): Number of ARQ requests received.
4Gon www.4Gon.co.uk [email protected] Tel: +44 (0)1245 808295 Fax: +44 (0)1245 808299